AC Repair and Installation Services in Chandler, AZ
All Out Heating and Cooling is a leading HVAC contractor dedicated to providing top-notch services in Chandler, AZ. Known for its high-tech industries, excellent schools, and vibrant cultural scene, Chandler blends suburban charm with urban amenities. Whether you’re enjoying a day at Tumbleweed Park, exploring the Arizona Railway Museum, or attending the Chandler Ostrich Festival, you can rely on All Out Heating and Cooling to keep your home comfortable all year round. Contact them today at 480-578-1370 or contact us online to schedule an appointment.
AC Repair and Maintenance
- Quick Diagnostics and Repairs: Expert technicians swiftly identify and repair issues to restore your comfort. From refrigerant leaks to electrical problems, we handle all types of AC repairs efficiently.
- Preventative Maintenance: Regular check-ups ensure your AC runs efficiently, reducing future repair costs. Services include cleaning filters, checking refrigerant levels, and inspecting electrical components.
- Emergency Repairs: Available 24/7 for urgent AC repairs to keep your home cool. Whether it’s a scorching summer afternoon or the middle of the night, we’re ready to restore your system.
- Thermostat Services: Installation and calibration of modern, programmable thermostats for optimal temperature control. Smart thermostats can help you save on energy bills while maintaining comfort.
- Seasonal Tune-Ups: Comprehensive system checks and tune-ups before peak summer months to ensure reliable performance. This includes inspecting coils, testing thermostats, and ensuring optimal airflow.
- Ductwork Inspection and Repair: Checking for leaks or damage in your ductwork to improve system efficiency and indoor air quality. Proper duct sealing can enhance your system’s performance and reduce energy costs.
Heating Services
- Heating System Repair: Fast heating system repairs to ensure your home stays warm during the colder months. Our experts can handle furnaces, heat pumps, and all heating-related issues.
- Heating Maintenance: Scheduled maintenance for long-lasting heating systems, including filter replacements, system inspections, and efficiency testing.
- Heating Installation: Modern heating system installations customized to your home’s needs. We install high-efficiency units to provide reliable warmth and reduce energy consumption.
Installation Services
- AC Installation: Professional installation of energy-efficient AC units. We assess your home’s cooling needs and recommend the best systems to ensure comfort and efficiency.
- Heating System Installation: Installation of modern heating systems tailored to your home. Our installations are designed to maximize efficiency and minimize operational costs.
Indoor Air Quality Solutions
- Air Duct Cleaning: Removing dust and allergens from your HVAC system to improve air quality and system efficiency. Clean ducts can help reduce allergy symptoms and improve overall health.
- Air Purifiers and Humidifiers: Installing systems that improve indoor air quality for a healthier living environment. We offer a range of products to help balance humidity levels and purify the air you breathe.
Emergency Services
- 24/7 Availability: Our team is always on standby for urgent HVAC issues. Day or night, weekends or holidays, we provide rapid response to get your system up and running.
Why Choose Us?
- Clear, Upfront Pricing: No hidden fees; what you see is what you get.
- Professional Technicians: Fully licensed and trained professionals who treat your home with respect.
- Preventative Solutions: Careful analysis and solving of issues to prevent future problems.
- Year-Round Maintenance: Options to keep your system working efficiently all year.
- Exceptional Customer Service: Consistently high ratings and positive customer feedback.
- Top-Of-The-Line Products: Representing the best and most reputable brands with the highest-rated warranties and guarantees.
Contact All Out Heating and Cooling Today
For all your HVAC needs in Chandler, AZ, trust All Out Heating and Cooling for reliable and efficient service. Whether you need a quick repair, regular maintenance, or a new installation, our team is ready to assist you. Our commitment to customer satisfaction and extensive experience in the industry make them the go-to choice for all HVAC services.
Call us now at 480-578-1370 to speak with a friendly representative or contact us online to schedule an appointment online. Don’t wait until a small issue becomes a major problem—reach out today to keep your home comfortable year-round.
Recent Jobs and Reviews in Chandler, AZ
Rated 5.0 out of 5 stars based on 3 customer reviews
Reviews
Great service. Ben was awesome
-
Overall Experience
-
Quality
-
Price
-
Convenience
Ben is fantastic!
-
Overall Experience
-
Quality
-
Price
-
Convenience
Excellent Service!
-
Overall Experience
-
Quality
-
Price
-
Convenience
Job Locations
George B.
Installed vent for microwave
Chandler, AZ 85226
George B.
Nest thermostat needed to be reconfigured because after by passing stat for heat and ac, the unit started to run in normal operation. stat said cooling and was actually heating and fan wasn’t running. Ac and heat run in normal operation at this time. Customer would like quote for new
Chandler, AZ 85226
George B.
Water stains look like they have been drying up and cannot find any freshwater tracks. Cleaned out drain line and noticed that it was a little backed up. I also dumped water along the evaporator coil down to the drip pan and noticed the drip pan seemed to be a little rushed out towards the west side and it could have been leaking throughout the summer and it’s just now showing signs in the office. Problem occurs with water leaking through the drip pan then the only suggestion to fix it is to replace the unit.
Chandler, AZ 85225
George B.
Heat pump and AC both run normal operation at this time. Suggested to customer to change out the filter once a month and not to reuse dirty ones.
Chandler, AZ 85248
George B.
I checked the AC unit and heat pump in Chandler, AZ, and found that pressures were normal. However, the temperature split was slightly off due to the ductwork. Despite this, both the AC and heat pump are running in normal operation at this time, with no major issues detected.
Chandler, AZ 85248
George B.
Cap existing duct work and add new 6 inch vent for kitchen. Duct seal all joints and supply and install new ridged pipe and register.
Chandler, AZ 85224
George B.
Confirmed Outlet was going to be in the right spot. Cabinets are going to be installed late next week.
Chandler, AZ 85226
George B.
Please reference pictures.
Chandler, AZ 85224
George B.
The capacitor for AC unit was reading 0 µF for fan and compressor. Replaced capacitor and did a temp split on the system and AC runs in normal operation at this time. Landlord confirmed, and wanted to go ahead with paying for the work order amount
Chandler, AZ 85226
George B.
Replace indoor coil under warranty
Indoor coil and filter dryer was replaced and brazed while flowing nitrogen system was then pressure tested at 250 psi and held for 10 minutes. Was then vacuumed down below 500 microns and held a standing vacuum test for 10 minutes. System was charged with factory charge of R410a refrigerant. System had a 10° sub cooling and a 20° temperature split.
Chandler, AZ 85286
George B.
Replace defrost control board and 3 pole contractor
Chandler, AZ 85225
George B.
Today I inspected the Goodman split system on the Casita and I found that the dual run capacitor was bubbled up. I tested the capacitor and was getting zeros across Both terminals. I installed a new dual capacitor and tested the Amra of the system to ensure proper operation. Upon departure system was getting a 20° temperature split. Homeowner also wanted to make sure that the package unit was cooling properly as well. Capacitors on that system are all good. And temperature split was 24°.
Replace dual run capacitor on casita
Chandler, AZ 85224
George B.
Upon inspection of the unit, I found it only getting an 8° temperature split. I also found There was excess water in the drain pan and Can clearly see oil contamination within the water. I checked pressures on the system and found it was indeed low on refrigerant. I inspected the condenser for any oil, residue or signs of leakage and found nothing. Homeowner agreed to repairs on estimate and System was topped off with 3 pounds of refrigerant to provide temporary cooling. Upon departure system was getting a 28° temperature split.
Chandler, AZ 85286
tre@callallout.com
Today I did a full maintenance on two American standard split systems. And here are my findings.
One system is getting a 20° temperature split the other is getting a 25 temperature split.
Both drain lines were blown out with nitrogen.
Both blower amps were within manufacturer specifications and Both blower wheels were also clean and free of debris.
Both blower capacitors were within tolerance range.
All gas safety controls are working properly.
At the condensers,
Both capacitors were within tolerance range. The amp draws on compressors and the outdoor fan motors were also within manufacturer specification.
Both condenser coils were chemically cleaned and rinsed.
Overall, both of these systems are in great condition and running within manufacturer specifications. Systems are both cooling properly upon departure.
Chandler, AZ 85286
George B.
Today I showed up to do a AC check up on two gas furnaces. Here are my findings, I found that the unit conditioning the bedrooms, all components were found to be within manufacture specifications. The unit that controls the main part of the house was found to have bad capacitors for the fan and the compressor. I’m recommending that we Replace 35/5 mfd dual capacitor in unit #1 (main). After replacing dual capacitor, I got a proper 20° temperature split and found that now the system is operating properly
Chandler, AZ 85225
tre@callallout.com
Replaced capacitor and hardstart kit under warranty. System is getting 19 degree temperature split upon departure.
Chandler, AZ 85226
George B.
Today I showed up to do a maintenance On a 23 year old, split gas unit and a 9 year-old split gas unit. Here are my findings, I found all components on both systems to be operating within manufacturer specifications. Homeowner requested we supply and install two new 20 x 25 x 4 Merv 11 air filters. No further thoughts or not at this time. gfc monthly
Chandler, AZ 85249
tre@callallout.com
I inspected the property and took pictures of the inside and the roof also took pictures of the blueprints With a mock up of a multihead mini split system. Owner The building is willing to go with a different idea Whatever is the most cost-efficient. Owner will also be sending blueprints and the lockbox code to George’s email.
Chandler, AZ 85225
George B.
Today I came to inspect a system for no cool. Here are my findings, I found That the person who is trying to switch out thermostats must have crossed wires, leading to a twenty four volt short popping the five amp fuse on the control board in the package unit. After replacing five amp fuse, System energized and all components were operating within manufacturer specifications.
Chandler, AZ 85225
George B.
4 ton Daikin split gas 14.5 SEER2 Single Stage compressor R32 refrigerant
System comes with a 12 year parts warranty and 6 year unit replacement warranty through Daikin. 2 year labor warranty thru All Out
Scope of work:
1. Protect the home with floor covers and drape plastic in closets and pantries as needed.
2. Remove & Replace the existing split system with a new AHRI rated split system with furnace/coil in the attic.
3. Supply & Install a new secondary drip pan with vibration isolators.
4. Supply & Install new custom fabricated duct distribution boxes (plenums) matched & sealed to the flange of the coil & furnace to prevent air leaks.
5. Supply & Install condensate overflow safety switch.
6. Supply & Install a new condensate EZ-trap with cleanouts and brush for ease of maintenance.
7. Supply & Install a new B-vent for furnace exhaust to existing roof penetration.
8. Supply & Install a heavy-duty electrical cord or service disconnect for the furnace.
9. Supply & Install gas
Chandler, AZ 85248
George B.
Today I showed up for a recall, Here are my findings. I found that all components were operating within manufacturer specifications. The system operating properly at this time.
Chandler, AZ 85224
George B.
Will provide quote for 4 ton split gas horizontal system.
Chandler, AZ 85248
George B.
Today I showed up for a service call and report. The thermostat was going blank and not cooling properly. Here are my findings. I found an upon inspection of thermostat the 24 V wire was not securely installed. After securing connection The thermostat began to operate properly and system began to cool. System working properly at this time. No further thoughts or notes.
Chandler, AZ 85225
George B.
Today I showed up to perform a no cool on a nine year old split gas system. Here are my findings, After a throw investigation, We found that the air filters we're extremely clogged with debris. This causing the lack of airflow. After replacing all filters, I've found all components to be operating within manufacturer specifications. No further thoughts or notes at this time.
Chandler, AZ 85248
George B.
Today I shown up for a no cool, here are the findings of my investigation. I recorded the 7.5 µF capacitor for the blower wheel out of tolerance. Once I replaced the 7.5 µF capacitor, System return to operating within manufacture specifications. No further thoughts or notes at this time.
Chandler, AZ 85224
Recent Jobs and Reviews in Chandler, AZ
Reviews
- Overall Experience
- Quality
- Price
- Convenience
- Overall Experience
- Quality
- Price
- Convenience
- Overall Experience
- Quality
- Price
- Convenience
Job Locations
Installed vent for microwave
Nest thermostat needed to be reconfigured because after by passing stat for heat and ac, the unit started to run in normal operation. stat said cooling and was actually heating and fan wasn’t running. Ac and heat run in normal operation at this time. Customer would like quote for new
Water stains look like they have been drying up and cannot find any freshwater tracks. Cleaned out drain line and noticed that it was a little backed up. I also dumped water along the evaporator coil down to the drip pan and noticed the drip pan seemed to be a little rushed out towards the west side and it could have been leaking throughout the summer and it’s just now showing signs in the office. Problem occurs with water leaking through the drip pan then the only suggestion to fix it is to replace the unit.
Heat pump and AC both run normal operation at this time. Suggested to customer to change out the filter once a month and not to reuse dirty ones.
I checked the AC unit and heat pump in Chandler, AZ, and found that pressures were normal. However, the temperature split was slightly off due to the ductwork. Despite this, both the AC and heat pump are running in normal operation at this time, with no major issues detected.
Cap existing duct work and add new 6 inch vent for kitchen. Duct seal all joints and supply and install new ridged pipe and register.
Confirmed Outlet was going to be in the right spot. Cabinets are going to be installed late next week.
Please reference pictures.
The capacitor for AC unit was reading 0 µF for fan and compressor. Replaced capacitor and did a temp split on the system and AC runs in normal operation at this time. Landlord confirmed, and wanted to go ahead with paying for the work order amount
Replace indoor coil under warranty Indoor coil and filter dryer was replaced and brazed while flowing nitrogen system was then pressure tested at 250 psi and held for 10 minutes. Was then vacuumed down below 500 microns and held a standing vacuum test for 10 minutes. System was charged with factory charge of R410a refrigerant. System had a 10° sub cooling and a 20° temperature split.
Replace defrost control board and 3 pole contractor
Today I inspected the Goodman split system on the Casita and I found that the dual run capacitor was bubbled up. I tested the capacitor and was getting zeros across Both terminals. I installed a new dual capacitor and tested the Amra of the system to ensure proper operation. Upon departure system was getting a 20° temperature split. Homeowner also wanted to make sure that the package unit was cooling properly as well. Capacitors on that system are all good. And temperature split was 24°. Replace dual run capacitor on casita
Upon inspection of the unit, I found it only getting an 8° temperature split. I also found There was excess water in the drain pan and Can clearly see oil contamination within the water. I checked pressures on the system and found it was indeed low on refrigerant. I inspected the condenser for any oil, residue or signs of leakage and found nothing. Homeowner agreed to repairs on estimate and System was topped off with 3 pounds of refrigerant to provide temporary cooling. Upon departure system was getting a 28° temperature split.
Today I did a full maintenance on two American standard split systems. And here are my findings. One system is getting a 20° temperature split the other is getting a 25 temperature split. Both drain lines were blown out with nitrogen. Both blower amps were within manufacturer specifications and Both blower wheels were also clean and free of debris. Both blower capacitors were within tolerance range. All gas safety controls are working properly. At the condensers, Both capacitors were within tolerance range. The amp draws on compressors and the outdoor fan motors were also within manufacturer specification. Both condenser coils were chemically cleaned and rinsed. Overall, both of these systems are in great condition and running within manufacturer specifications. Systems are both cooling properly upon departure.
Today I showed up to do a AC check up on two gas furnaces. Here are my findings, I found that the unit conditioning the bedrooms, all components were found to be within manufacture specifications. The unit that controls the main part of the house was found to have bad capacitors for the fan and the compressor. I’m recommending that we Replace 35/5 mfd dual capacitor in unit #1 (main). After replacing dual capacitor, I got a proper 20° temperature split and found that now the system is operating properly
Replaced capacitor and hardstart kit under warranty. System is getting 19 degree temperature split upon departure.
Today I showed up to do a maintenance On a 23 year old, split gas unit and a 9 year-old split gas unit. Here are my findings, I found all components on both systems to be operating within manufacturer specifications. Homeowner requested we supply and install two new 20 x 25 x 4 Merv 11 air filters. No further thoughts or not at this time. gfc monthly
I inspected the property and took pictures of the inside and the roof also took pictures of the blueprints With a mock up of a multihead mini split system. Owner The building is willing to go with a different idea Whatever is the most cost-efficient. Owner will also be sending blueprints and the lockbox code to George’s email.
Today I came to inspect a system for no cool. Here are my findings, I found That the person who is trying to switch out thermostats must have crossed wires, leading to a twenty four volt short popping the five amp fuse on the control board in the package unit. After replacing five amp fuse, System energized and all components were operating within manufacturer specifications.
4 ton Daikin split gas 14.5 SEER2 Single Stage compressor R32 refrigerant System comes with a 12 year parts warranty and 6 year unit replacement warranty through Daikin. 2 year labor warranty thru All Out Scope of work: 1. Protect the home with floor covers and drape plastic in closets and pantries as needed. 2. Remove & Replace the existing split system with a new AHRI rated split system with furnace/coil in the attic. 3. Supply & Install a new secondary drip pan with vibration isolators. 4. Supply & Install new custom fabricated duct distribution boxes (plenums) matched & sealed to the flange of the coil & furnace to prevent air leaks. 5. Supply & Install condensate overflow safety switch. 6. Supply & Install a new condensate EZ-trap with cleanouts and brush for ease of maintenance. 7. Supply & Install a new B-vent for furnace exhaust to existing roof penetration. 8. Supply & Install a heavy-duty electrical cord or service disconnect for the furnace. 9. Supply & Install gas
Today I showed up for a recall, Here are my findings. I found that all components were operating within manufacturer specifications. The system operating properly at this time.
Will provide quote for 4 ton split gas horizontal system.
Today I showed up for a service call and report. The thermostat was going blank and not cooling properly. Here are my findings. I found an upon inspection of thermostat the 24 V wire was not securely installed. After securing connection The thermostat began to operate properly and system began to cool. System working properly at this time. No further thoughts or notes.
Today I showed up to perform a no cool on a nine year old split gas system. Here are my findings, After a throw investigation, We found that the air filters we're extremely clogged with debris. This causing the lack of airflow. After replacing all filters, I've found all components to be operating within manufacturer specifications. No further thoughts or notes at this time.
Today I shown up for a no cool, here are the findings of my investigation. I recorded the 7.5 µF capacitor for the blower wheel out of tolerance. Once I replaced the 7.5 µF capacitor, System return to operating within manufacture specifications. No further thoughts or notes at this time.